hydrogen-banner

500Nm3/h PSA Nitrogen Generator (PSA N2 Plant)

500Nm3/h PSA Nitrogen Generator (PSA N2 Plant)

Plant features of the PSA Nitrogen Generation plant:

1. It does not contain H2, and is suitable for occasions where hydrogen and oxygen are strictly required.

2. The energy saving technology reduces the energy consumption of the system greatly.

3. The Double tower structure is applied for deoxygenation, which can add or replace carbon carried catalyst without stopping.

4. The Quality of finished products are guaranteed by the automatic vent device of national patent technology.

5. The key components in the system are world famous brands, which is an effective guarantee for the quality of the equipment.

6. It has many functions of fault diagnosis, alarm and automatic processing.

7. Optional touch screen display, dew point detection, energy saving control, DCS communication and so on.

8. Simple operation, stable performance, high automation level.

9. Modular design, high integration.

The PSA Nitrogen Plant Data:

Project Location: South Korea

Application: Industrial use

Description

Value

Description

Value

Nitrogen flow rate

500Nm3/h

Nitrogen purity

99.9%

Nitrogen pressure

0.8MPa

Dew point of nitrogen

-40℃

High concentration nitrogen flow rate

450Nm3/h

High concentration nitrogen purity

99.999%

High concentration nitrogen pressure

0.7MPa

Dew point of  High concentration nitrogen

-60℃

Condition of power supply

Type

Value

Remarks

220V/50Hz

0.15KW

Nitrogen generator control electricity

220V/50Hz

7.5KW

Cooling machine

380V/50Hz

73.5/KW

Carbon-loaded purification equipment

Feed gas condition

Feed gas quality

Flow rate

33.86m³/min

pressure

≥1.0MPa

Nitrogen content

78.1%(V)

Temperature

≤45℃

Dust size

≤5μm

Oil content

≤3mg/m3

CO2

≤350ppm

C2H2

≤0.5ppm

CnHm

≤30ppm

∑(NOx+SO2+HCl+Cl2)

≤8ppm

Cooling water conditions

Feed water pressure

0.2~0.4MPa(G)

Temperature of feed water

≤30℃

pH value

7.8~8.3

Suspended matter content

≤10mg/L

Total hardness

≤5mmol/L

Cooling water consumption

16.2T/h

Equipment installation and operating environment

Ambient temperature:

2℃~40℃

Relative humidity:

≤80%

Atmospheric pressure:

80kPa~106kPa

Dry, clean, well ventilated, and free of corrosive substances around.

Additional/Optional Features For PSA Nitrogen Generation Units:

Upon request, TCWY offers individually plant supply involving air compressor, nitrogen generator, nitrogen filling station (nitrogen booster, filling mainfold, filling rack and gas cylinder etc.