- Typical feed: Air
- Capacity range: 300~30000Nm3/h
- O2 purity: up to 93% by vol.
- O2 supply pressure: according to customer’s requirement
- Operation: automatic, PLC controlled
- Utilities: For the production of 1,000 Nm³/h O2 (purity 90%), the following Utilities are required:
- Installed power of main engine: 500kw
- Circulating cooling water: 20m3/h
- Circulating sealing water: 2.4m3/h
- Instrument air: 0.6MPa, 50Nm3/h
* The VPSA oxygen production process implements “customized” design according to the user’s different altitude, meteorological conditions, device size, oxygen purity (70%~93%).