hydrogen-banner

Products

  • Skid Steam Methane Reformer for ON-SITE Hydrogen Production

    Skid Steam Methane Reformer for ON-SITE Hydrogen Production

    • Operation: automatic, PLC controlled
    • Utilities: For the production of 1,000 Nm³/h H2 from natural gas the following Utilities are required:
    • 380-420 Nm³/h natural gas
    • 900 kg/h boiler feed water
    • 28 kW electric power
    • 38 m³/h cooling water *
    • * can be substituted by air cooling
    • By-product: export steam, if required
  • TCWY’s  Carbon Capture Solutions

    TCWY’s Carbon Capture Solutions

    • CO2 Removal
    • Typical feed: LNG, refinery dry gas, syngas etc.
    • CO2 content: ≤50ppm

     

    • CO2 Recovery
    • Typical feed: CO2-rich Gas Mixture (Boiler flue gas, power plant flue gas, kiln gas etc.)
    • CO2 purity: 95%~99% by vol.

     

    • Liquid CO2
    • Typical feed: CO2-rich Gas Mixture
    • CO2 purity: according to customer’s requirement
  • Natural Gas SMR Hydrogen Production Plant

    Natural Gas SMR Hydrogen Production Plant

    • Typical feed: Natural gas, LPG, naphtha
    • Capacity range: 10~50000Nm3/h
    • H2 purity: Typically 99.999% by vol. (optional 99.9999% by vol.)
    • H2 supply pressure: Typically 20 bar (g)
    • Operation: Automatic, PLC controlled
    • Utilities: For the production of 1,000 Nm³/h H2 from natural gas the following Utilities are required:
    • 380-420 Nm³/h natural gas
    • 900 kg/h boiler feed water
    • 28 kW electric power
    • 38 m³/h cooling water *
    • * can be substituted by air cooling
    • By-product: Export steam, if required
  • Methanol Cracking Hydrogen Production Plant

    Methanol Cracking Hydrogen Production Plant

    • Typical feed: Methanol
    • Capacity range: 10~50000Nm3/h
    • H2 purity: Typically 99.999% by vol. (optional 99.9999% by vol.)
    • H2 supply pressure: Typically 15 bar (g)
    • Operation: Automatic, PLC controlled
    • Utilities: For the production of 1,000 Nm³/h H2 from methanol, the following Utilities are required:
    • 500 kg/h methanol
    • 320 kg/h demineralised water
    • 110 kW electric power
    • 21T/h cooling water
  • Oxygen Generator PSA Oxygen Plant (PSA-O2 Plant)

    Oxygen Generator PSA Oxygen Plant (PSA-O2 Plant)

    • Typical feed: Air
    • Capacity range: 5~200Nm3/h
    • O2 purity: 90%~95% by vol.
    • O2 supply pressure: 0.1~0.4MPa(Adjustable)
    • Operation: automatic, PLC controlled
    • Utilities: For the production of 100 Nm³/h O2, the following Utilities are required:
    • Air consumption: 21.7m3/min
    • Power of air compressor: 132kw
    •  Power of oxygen generator purification system: 4.5kw
  • Nature Gas to CNG/LNG Plant

    Nature Gas to CNG/LNG Plant

    • Typical feed: Natural, LPG
    • Capacity range: 2×10⁴ Nm³/d~500×10⁴ Nm³/d (15t/d~100×10⁴t/d)
    • Operation: Automatic, PLC controlled
    • Utilities: the following Utilities are required:
    • Natural gas
    • Electric power
  • Biogas to CNG/LNG Plant

    Biogas to CNG/LNG Plant

    • Typical feed: Biogas
    • Capacity range: 5000Nm3/d~120000Nm3/d
    • CNG supply pressure: ≥25MPaG
    • Operation: Automatic, PLC controlled
    • Utilities: the following Utilities are required:
    • Biogas
    • Electric power
  • H2S Removal Plant

    H2S Removal Plant

    • Typical feed: H2S-rich Gas Mixture
    • H2S content: ≤1ppm by vol.
    • Operation: Automatic, PLC controlled
    • Utilities: the following Utilities are required:
    • Electric power
  • Nitrogen Generator PSA Nitrogen Plant (PSA-N2 Plant)

    Nitrogen Generator PSA Nitrogen Plant (PSA-N2 Plant)

    • Typical feed: Air
    • Capacity range: 5~3000Nm3/h
    • N2 purity: 95%~99.999% by vol.
    • N2 supply pressure: 0.1~0.8MPa(Adjustable)
    • Operation: Automatic, PLC controlled
    • Utilities: For the production of 1,000 Nm³/h N2, the following Utilities are required:
    • Air consumption: 63.8m3/min
    • Power of air compressor: 355kw
    •  Power of nitrogen generator purification system: 14.2kw
  • Vacuum Pressure Swing Adsorption Oxygen Production Plant (VPSA-O2 Plant)

    Vacuum Pressure Swing Adsorption Oxygen Production Plant (VPSA-O2 Plant)

    • Typical feed: Air
    • Capacity range: 300~30000Nm3/h
    • O2 purity: up to 93% by vol.
    • O2 supply pressure: according to customer’s requirement
    • Operation: automatic, PLC controlled
    • Utilities: For the production of 1,000 Nm³/h O2 (purity 90%), the following Utilities are required:
    • Installed power of main engine: 500kw
    • Circulating cooling water: 20m3/h
    • Circulating sealing water: 2.4m3/h
    • Instrument air: 0.6MPa, 50Nm3/h

    * The VPSA oxygen production process implements “customized” design according to the user’s different altitude, meteorological conditions, device size, oxygen purity (70%~93%).

  • Hydrogen Recovery Plant PSA Hydrogen Purification Plant (PSA-H2 Plant)

    Hydrogen Recovery Plant PSA Hydrogen Purification Plant (PSA-H2 Plant)

    • Typical feed: H2-rich Gas Mixture
    • Capacity range: 50~200000Nm³/h
    • H2 purity: Typically 99.999% by vol. (optional 99.9999% by vol.)& Meet hydrogen fuel cell standards
    • H2 supply pressure: according to customer’s requirement
    • Operation: Automatic, PLC controlled
    • Utilities: the following Utilities are required:
    • Instrument Air
    • Electrical
    • Nitrogen
    • Electric power